Thermally Modified Hardwood Applications in Mass Timber Construction

Research on hybrid cross-laminated timber shows how thermally modified hardwood can improve moisture durability.

Why Thermally Modified Wood (TMW) in CLT?
Cross-laminated timber (CLT) is helping move commercial construction toward renewable, lower-carbon materials. Its strength, light weight, prefabrication potential, and architectural appeal make it suitable for walls, floors, and roofs. Yet moisture remains a limitation, particularly during construction and in humid environments. Exterior cladding is typically needed to protect CLT from weather exposure. Repeated wetting and drying can cause swelling, shrinkage, checking, warping, and bond line delamination. Trapped moisture can also create conditions favorable for biological deterioration. Improving moisture durability could therefore expand where and how mass timber is used.
A Hybrid Approach
Thermally modified wood offers one possible solution. During thermal modification, wood is treated in a controlled, low-oxygen environment, changing its chemistry, reducing moisture absorption, improving dimensional stability, and increasing decay resistance. The wood darkens to a uniform appearance, benefiting visual appearance applications.
The authors evaluated hybrid CLT made with unmodified yellow-poplar in the core and thermally modified yellow-poplar in the outer layers. Yellow-poplar is abundant throughout the Appalachian region and has considerable potential for structural products.
Placing thermally modified wood only where moisture exposure is greatest may provide durability benefits while retaining stronger, unmodified wood inside the panel and minimizing cost.
What We Learned
Test results of individual boards showed that thermally modified yellow-poplar had approximately 48% greater resistance to water-vapor movement than unmodified yellow-poplar. In three-layer CLT panels, hybrid CLT (TMW and unmodified wood) exhibited approximately 57% greater water-vapor resistance than conventional yellow-poplar CLT (all unmodified wood).
After 40 days under high-moisture conditions, hybrid panels absorbed approximately half as much moisture as conventional three-layer panels. The hybrid configuration also exhibited 77% less volumetric swelling, indicating substantially improved dimensional stability and a reduced risk of checking and cracking.
CLT panels were also tested outdoors under prolonged wetting and natural weathering, conditions that can cause swelling, checking, and delamination. In one test, water remained pooled on the panel surface for one week to simulate extended exposure to rain. Early in the natural drying process, the middle layer of the hybrid panel retained less moisture than that of the control, indicating that moisture trapped within a panel dries slowly and can increase the risk of internal deterioration and delamination.
After one year of natural weathering, the five-layer hybrid CLT had no delamination in the glued layers, whereas the control panels developed substantial delamination. Small surface checks formed in the thermally modified outer layers, but they did not extend into the inner layers.
Where the Opportunity Lies
This work demonstrates that hybrid panels could result in new markets for thermally modified hardwoods in moisture-exposed mass timber components, building envelopes, and applications where dimensional stability and appearance are important. The approach is also resource-efficient because modified wood is used as a protective outer layer rather than throughout the entire panel.
Looking Ahead
Moving forward will require evaluating full-scale panels for mechanical performance and connection behavior, testing assemblies across different climates and repeated wetting-and-drying cycles, pursuing code acceptance, and developing standardized manufacturing guidance.
Thermally modified wood is not yet a universal solution for mass timber. However, hybrid CLT offers a promising approach by placing moisture-resistant wood where protection is needed while retaining the strength of unmodified wood in the panel interior.
References
Masoumi, A., Bond, B. H., Hindman, D. P., Zink Sharp, A., & Nguegang Nkeuwa, W. (2026). Adhesive bonding quality of cross-laminated timber made of thermally modified and unmodified wood. European Journal of Wood and Wood Products, 84, Article 122. https://doi.org/10.1007/s00107-026-02481-7
Masoumi, A., & Bond, B. H. (2026). Outdoor moisture durability of hybrid cross-laminated timber. Forest Products Journal, 76(3), 346–349. https://doi.org/10.13073/FPJ-D-26-00006
By ABASALI MASOUMI AND BRIAN BOND